Dca vantage maintenance log sheet pdf

Dca vantage measuring instruments pdf manual download. Vantage user guide, dca hba1c or dca microalbumin creatinine instructions for use and the dca hba1cmicroalbumin creatinine quality control instruction for use. Community forums for siemens dca vantage relating to control log sheets on medwrench. Siemens healthineers 10311161 hba1c normalabnormal control combination kit. Download forms and certificates, inservice training tools, and product documentation for the clinitek advantus urine chemistry analyzer, clinitek status family of analyzers, dca vantage analyzer, urinalysis test strips and xprecia stride coagulation analyzer. The siemens dca vantage analyzer drives diabetic patient compliance with trusted, clinically proven results.

Dca vantage analyzer starter kit by siemens medline. Dca vantage aic analyzer maintenance logsheet week week week. Dca vantage analyzer and accessories by siemens healthcare manufacturer. Clean spring, changeclean air filter, and perform optical test. Drive diabetic patient compliance with trusted, clinically. It is indended to be used to monitor longterm glycemic control of known diabetic patients. The product increases patient comfort by requiring a smaller whole blood sample 1 ul for hba1c and provides hba1c patient trend graph. Siemens diagnostics air filter kit for the dca vantage. May 28, 2019 drive diabetes patient compliance using the dca vantage analyzer with clinically proven hba1c1, albumin and creatinine tests and albumintocreatinine a. The dca vantage analyzer helps you monitor glycemic control and detect early. Call or contact us for pricing and availability 369966820 or 1877wilburn 18779452876. Dca vantage is a light weight instrument weighing 3.

Dca vantage analyzer helps you better manage diabetes patients by providing. The test principle for the measurement of hba1c using this analyser is by inhibition of latex. Prepare control materials reconstitute a normal and abnormal hba1c control or a low and high microalbumin control by following the directions in the control package insert sheet keep the control barcode card provided in. Siemens diagnostics dca vantage analyzer for diabetes care. Dca vantage aic analyzer maintenance logsheet week week week week week week week week 1 1 1 january march april 3 june july x x x week week week week february 1 quarterl 1 maintenance may 4 quarterly maintenance august 1 quarterly maintenance november 1 quarterly maintenance september october december quarterly maintenance change air filter. Results in minutes enable actionable physicianpatient conversations at the time of visit. Document all maintenance on the dca vantage maintenance log. Home laboratory glucose a1c analyzers and accessories air filter kit for the dca vantage analyzer 400 series. Use the up and down arrows to view all of the maintenance entries. Idexx catalyst dx chemistry analyzer maintenance log year.

The siemens dca vantage hba1c analyser is a small spectrophotometer using absorbance. Siemens dca vantage analyser for hba1c effective date. Evaluation of the dca vantage analyzer for hba1c assay. Siemens dca vantage wilburn medical usa 18779452876. The system delivers the simplicity and convenience required at the point of care with no sample or reagent preparation steps. Hemoglobin a1c dca vantage procedure bassett healthcare. Barcode scanner for safe and rapid operator and patient i. The dca vantage analyzer is the diabetes system that delivers clinically proven, clinically relevant hba1c and a. Meet labquality testing standards with an analyser that speeds and simplifies diabetes tests and delivers. E, 201208 page 2 no part of this manual or the products it describes may be reproduced by any means or in any form without prior consent in writing from siemens healthcare diagnostics.

The siemens dca vantage is a device used for the quantitatve measurement of hemoglobin a 1c in blood. The diabetes integration project will operate the following point of care analyzers. C ratio results shown to improve patient compliance. S047763 equipment and validation records are stored. Allow a free hanging blood drop to form before collecting a sample. Genexpert poc covid pcr 3023801 sarscov2 patient fact sheet. Simple enough to use in your office or clinic, and yet powerful enough to deliver labquality performance at the point of care. General information the dca vantage analyser dca is a portable medical device used for point. To ensure proper performance of the unit, the instructions should be thoroughly understood and followed. Siemens dca vantage refurbished block scientific inc. Mckesson medical surgical is a medical distributor of medical supplies, durable medical equipment, surgical supplies, medical lab supplies, and more. Mark the checkbox and tape the optical test print out in the space provided to indicate completion. The procedure provides instructions for hba1c quality control testing with the dca vantage. It is designed to quantitatively measure the percent of hemoglobin a.

Siemens dca vantagedrive diabetic patient compliance with trusted, clinically proven. The dca vantage tm analyser helps you monitor glycaemic control and detect early kidney disease in environments ranging from the physicians office to remote, point of care coordinated sites in hospitals and multisite practices. Add to quarterly maintenance to send a comparison sample to the laboratory. Dca vantage analyzer and accessories by siemens healthcare. The siemens dca vantage analyser is a portable analyser for the quantitative measurement of haemoglobin a1c hba1c in whole blood at the point of care. Record on the carton, the date the carton was placed at room temperature. We have 1 siemens dca vantage manual available for free pdf download. The dca vantage analyzer is critical for monitoring a patients glycemic control and helps physicians to encourage patient compliance by delivering actionable test results during a patient visit. Each mobile team will utilize two dca and one piccolo analyzer. Dca vantage analyzer, 1 dca hba1c reagent kit, 1 dca hba1c normal and abnormal controls kit, 12 month standard plus 2year extended warranty dimensions 9 x 10 x 1112 inch. Analyzer lets you monitor glycemic control and detect early kidney disease with fast, actionable test results that can help you assess the effectiveness of a treatment plan and make adjustments. Dca vantage analyzer helps you better manage diabetes patients by providing quick results to enable actionable physicianpatient conversations at the time of the visit.

Page 1 dca vantage a n a l y z e r operators guide ref 06489264 rev. To delete all maintenance log entries, select delete all 8. Point of care testing manual ucsf clinical laboratories. The dca vantage is a semiautomated, benchtop system. Any printed copies are uncontrolled unless specified. Provide the clinical confidence your patients deserve. It is designed to quantitatively measure the percent of hemoglobin a1c in blood and low concentrations of albumin in urine micr oalbuminuria, creatinine in urine, and the albumincreatinine ratio in urine.

Siemens healthcare analyzer lets you monitor glycemic control and detect early kidney disease with fast, actionable test results that can help you assess the effectiveness of a treatment plan and make adjustments. The dca vantage system is intended for professional use in a physicians office or hospital laboratory. Hba1c testing with the siemens dca vantage drive diabetes patient compliance with clinically proven and clinically relevant hba1c, albumin, creatinine, and albumintocreatinine a. The inservice will include familiarization with the equipment and its components, system setup and operation, maintenance, troubleshooting, and handson training and return demonstration. C ratio testing results in just six and seven minutes, respectively. Siemens dca vantage community, manuals and specifications. This page has moved to please update any bookmarks you may have saved locally. The cvs for the haemoglobin and hba1c levels measured on ten independently fabricated paperbased sheets. Diabetes care analysers dca phc remote guideline nt health. Siemens dca vantage analyzer for efficient pointofcare. Maintenance schedule for support, contact poct technologist email. Very easy to use individually packaged reagent cassettes no sample preparation reliable hba1c results in approximately 6 minutes from just 1. Dca vantage maintenance log weekly and as needed dateinitials. The dca vantage analyzer helps you monitor glycemic control and detect early kidney disease in environments ranging from the physicians office to remote, pointofcare coordinated sites in hospitals and multisite practices.

You can add community subscriptions in the search bar that says subscribe to more communities. Dca vantage log sheets compiled pdf, doc, ppt dca vantage log sheets fast download. Monitor glycemic control and detect early kidney disease the dca vantage analyzer simplifies diabetes testing, delivering accurate,1 clinically relevant results during the patient visit to help physicians and nurses improve patient decisionmaking2,3 and diabetic patient compliance. No part of this manual or the products it describes may be reproduced by any means or in any form without prior consent in writing from. Dca vantage maintenance log weekly and as needed date initials. Need help where to get a copy of the control log sheets reply. Record all qc results in the poct results log sheet. Keep the manual in a readily accessible location for future reference.

The dca vantage system is a semiautomated, benchtop system. The dca vantage is a semiautomated, bench top system. For audit purposes, log sheets are available to document patient tests, qc, calibration and maintenance if analyzer is not interfaced. Dca vantage analyzer the dca vantage analyzer helps monitor glycemic control and detect early kidney disease in patients with diabetes. The dca vantage system is intended for professional use in a physicians. In case of continuing failure contact cruinn diagnostics ltd. Siemens dca vantage for hba 1c nmh department of pathology 1 description. The dca vantage analyzer is a pointofcare system that helps you monitor. The siemens dca vantage is a device used for the quantitatve measurement of hemoglobin a1c. Dca vantage aic analyzer maintenance logsheet week week week week week week week week 1 1 1 january march april 3 june july x x x. Ceqal has assessed the analytical performance of the point of care testing analyzers that are being used by the north, dauphin and south mobile teams. Vantage series 2200 scope this manual contains information concerning the installation, operation and maintenance of the vantage 22102220. The clinical specialist will walk your facility through the inservice packet that came with your new unit and help you understand the importance of the.

It is designed to quantitatively measure the percent of haemoglobin a1c in blood and low concentrations of albumin in urine microalbuminuria, creatinine in urine, and the albumincreatinine ratio in urine. Our dca tm hba1c and dca microalbumin creatinine tests are clinically proven1,2,3,4 and the most widely used5 brands. Jun 25, 2018 the siemens dca vantage pointofcare analyzer an ideal option for diabetes management in physicians offices, pointofcare coordinated sites in hospitals, and multisite practices. After loading the reagent test cartridge into the dca vantage, the test result will be displayed in six minutes. It is designed to quantitatively measure the percent of hemoglobin a1c in blood and low concentrations of albumin in urine microalbuminuria, creatinine in urine, and the albumincreatinine ratio in urine. Siemens dca vantage operators manual pdf download manualslib. To calibrate the dca vantage with new lot number of ha1c reagent cartridge. The purpose of this quick setup guide is to instruct the. Prepare control materials reconstitute a normal and abnormal hba1c control or a low and high microalbumin control by following the directions in the control package insert sheet keep the control barcode card provided in the kit. Dca 2000, dca, and dca vantage are trademarks of siemens healthcare. We have remained at the forefront of medicine by fostering a culture of collaboration, pushing the boundaries of medical research, educating the brightest medical minds and maintaining an unwavering commitment to the diverse communities we serve. The dca vantage tm analyser is a semiautomated, bench top system.

Dca vantage maintenance log fill online, printable, fillable. Cw\point of care\hemoglobin a1c this is a controlled document for cw use only. No longer do siemens clients in primary care need to buy expensive and complex poc data management software systems, not suited for their needs. Simple enough to use in your office lab, and yet powerful enough to deliver labquality performance in pointofcare coordinated settings.

Siemens dca vantage analyser for hba1c copy royal united. When prompted clean the internal components of the analyzer. No part of this manual or the products it describes may be reproduced by any means or in any form. View online or download siemens dca vantage operators manual. Quantitative measurement of hemoglobin a1c on the dca. Perform optical test and record results on the optical test log sheet. Quantitative measurement of hemoglobin a1c on the dca vantage. An internal validation study 5 results precision study dca hba1c test precision at concentrations of 31 mmolmol 5.

620 1244 1131 45 26 704 1199 1059 1112 337 459 1055 1046 1161 1370 251 1585 328 851 730 749 731 1098 665 777 328 1517 549 1355 1172 1111